Instruction Manual
Standard Diffusion Eagle Series
Portable Multi-Gas Detector
Part Number: 71-0042RK
Revision: 0
Released: 2/11/03
Vista de página 0
1 2 3 4 5 6 ... 65 66

Resumo do Conteúdo

Página 1 - Instruction Manual

RKI Instruments, Inc. • 33248 Central Ave, Union City, CA 945874 • (510) 441-5656 Instruction ManualStandard Diffusion Eagle Series Portable Multi-G

Página 2 - Warranty

Diffusion Eagle Instruction Manual Description: Eagle and Remote Detector • 5Description: Eagle and Remote DetectorEagle CaseThe Eagle has a plastic c

Página 3 - Table of Contents

6 • Description: Eagle and Remote Detector Diffusion Eagle Instruction ManualAlarm LightsTwo ultra-bright, red, light-emitting diodes (LEDs) provide v

Página 4

Diffusion Eagle Instruction Manual Description: Eagle and Remote Detector • 7Methane Elimination SwitchThe methane elimination switch (SW1) is mounted

Página 5

8 • Description: Eagle and Remote Detector Diffusion Eagle Instruction ManualInterconnect Circuit BoardThe Remote Detector has a printed circuit board

Página 6 - Introduction

Diffusion Eagle Instruction Manual Description: Eagle and Remote Detector • 9SensorsUnder normal conditions, the Eagle’s standard sensors have an oper

Página 7 - About this Manual

10 • Description: Eagle and Remote Detector Diffusion Eagle Instruction ManualStandard toxics (CO and H2S) sensorsThe carbon monoxide (CO) and hydroge

Página 8 - Specifications

Diffusion Eagle Instruction Manual Operation • 11OperationThe Eagle has four operating modes: normal operating mode, display mode, setup mode, and cal

Página 9 - 2 PPM (Parts Per Million)

12 • Operation Diffusion Eagle Instruction Manual•To attach the Remote Detector directly to the Eagle, position the Remote Detector coupling in the un

Página 10 - Control Panel

Diffusion Eagle Instruction Manual Operation • 13NOTE: If the Remote detector has been disconnected from the Eagle for more than a few minutes, such a

Página 11 - Circuit Boards

14 • Operation Diffusion Eagle Instruction Manual2. Press and briefly hold down the POWER/ENTER button. If the Lunch Break feature is on (see page 38),

Página 12 - CAL/SETUP Switch

WarrantyDiffusion Eagle Instruction Manual Warranty RKI Instruments, Inc., warrants gas alarm equipment manufactured by RKI and sold by RKI to be fre

Página 13 - Interconnect Circuit Board

Diffusion Eagle Instruction Manual Operation • 15NOTE: The following screen only displays if the data logging option is installed. If the data logging

Página 14 - Oxygen sensor

16 • Operation Diffusion Eagle Instruction Manual3. Verify that the Eagle is operating correctly. Use the RKI Bump Test Kit to easily verify correct o

Página 15 - Connector

Diffusion Eagle Instruction Manual Operation • 17Monitoring Combustible Gases Other than MethaneIf the combustible gas sensor is calibrated to methane

Página 16 - Operation

18 • Operation Diffusion Eagle Instruction ManualSetting User AccessThe CAL/SETUP switch controls the Eagle functions available to the user. The switc

Página 17 - Counterclockwise to Locked

Diffusion Eagle Instruction Manual Alarms • 19AlarmsAlarm IndicationsThis section describes the Eagle’s audible and visual alarm indications for gas,

Página 18 - Diffusion Ea

20 • Alarms Diffusion Eagle Instruction ManualSTEL alarm (toxics only)If a toxic gas channel’s average gas reading for the past 15 minutes exceeds the

Página 19 - Extender Cable

Diffusion Eagle Instruction Manual Alarms • 21Low battery alarmWhen the battery charge drops near the lower limit, the Eagle displays the following sc

Página 20

22 • Alarms Diffusion Eagle Instruction ManualIf the sensor failed during start-up, the Eagle continues with the normalstart-up sequence after the fai

Página 21 - Normal Operation

Diffusion Eagle Instruction Manual Display Mode • 23Display ModeThe Eagle has four operating modes: normal operating mode, display mode, setup mode, a

Página 22

24 • Display Mode Diffusion Eagle Instruction ManualTo enter a user and station ID:To scroll to the next screen at any time, press the DISP/ADJ button

Página 23 - Turning Off the Eagle

Diffusion Eagle Instruction Manual Table of Contents Table of Contents Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 24 - Alarm Indications

Diffusion Eagle Instruction Manual Display Mode • 25TWA/STEL ScreenThe TWA/STEL screen displays the time-weighted average (TWA) and the short-term exp

Página 25 - 20 • Alarms Diffusion Ea

26 • Display Mode Diffusion Eagle Instruction ManualClear Data Logger ScreensCAUTION: Once you clear the Data Logger, you cannot retrieve any data pre

Página 26

Diffusion Eagle Instruction Manual Setup Mode • 27Setup ModeNOTE: The screens illustrated in this section are examples only. The screens displayed by

Página 27 - Resetting Gas Alarms

28 • Setup Mode Diffusion Eagle Instruction ManualTips for Using Setup Mode•To select a menu option, use the AIR/▲ or SHIFT/▼ button to place the prom

Página 28 - Display Mode

Diffusion Eagle Instruction Manual Setup Mode • 292. Press the AIR/▲ or SHIFT/▼ button to display the desired setting. CAUTION: This setting should al

Página 29 - Elapsed Time Screen

30 • Setup Mode Diffusion Eagle Instruction Manual5. Press the POWER/ENTER button to enter the new target gas label.A screen displays that shows the f

Página 30 - Date/Time Screen

Diffusion Eagle Instruction Manual Setup Mode • 313. Press the POWER/ENTER button to enter the displayed character. The next character flashes.4. Repea

Página 31 - Remaining Log Time Screen

32 • Setup Mode Diffusion Eagle Instruction ManualReturning to the main menu1. Press the SHIFT/▼ button. The ESCAPE message displays. (Press the AIR/▲

Página 32 - Setup Mode

Diffusion Eagle Instruction Manual Setup Mode • 33Updating the full-scale setting1. Press the SHIFT/▼ button to place the prompt in the second line, t

Página 33 - Entering Setup Mode

34 • Setup Mode Diffusion Eagle Instruction ManualUpdating the target gas label1. From the main menu, select the GAS COMBINATIONS menu option.2. Press

Página 34 - Updating Channel Settings

Table of Contents Diffusion Eagle Instruction Manual Display Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 35 - 30 • Setup Mode Diffusion Ea

Diffusion Eagle Instruction Manual Setup Mode • 35Updating the full-scale setting1. Press the SHIFT/▼ button to place the prompt in the second line, t

Página 36 - Equivalent to 100% LEL

36 • Setup Mode Diffusion Eagle Instruction ManualUpdating Combustible Gas Channel Units of MeasureThis setting allows you to display the combustible

Página 37 - 32 • Setup Mode Diffusion Ea

Diffusion Eagle Instruction Manual Setup Mode • 37If this is the alarm point you want to update, continue with step 3. If not, continue pressing the P

Página 38

38 • Setup Mode Diffusion Eagle Instruction ManualUpdating the Lunch Break SettingWith Lunch Break OFF (default), the Eagle automatically starts new T

Página 39 - 34 • Setup Mode Diffusion Ea

Diffusion Eagle Instruction Manual Setup Mode • 39Updating the Alarm Silence SettingNOTE: This feature works only when Alarm Latching is turned on.Wit

Página 40

40 • Setup Mode Diffusion Eagle Instruction ManualUpdating the Auto Calibration SettingsThe Eagle stores default calibration settings. This allows you

Página 41 - 36 • Setup Mode Diffusion Ea

Diffusion Eagle Instruction Manual Setup Mode • 41Updating the Back Light SettingThis setting indicates the length of time the LCD illuminates when yo

Página 42

42 • Setup Mode Diffusion Eagle Instruction ManualUpdating the Interval Time Setting (data log option)This setting indicates how often the Eagle recor

Página 43 - 38 • Setup Mode Diffusion Ea

Diffusion Eagle Instruction Manual Setup Mode • 43Updating the Time Calibration Setting (data log option)This setting indicates how often the Eagle al

Página 44

44 • Setup Mode Diffusion Eagle Instruction ManualUpdating the Confirmation Beep SettingWith Confirmation Beep ON, the Eagle beeps once every 15 minutes

Página 45 - 40 • Setup Mode Diffusion Ea

Diffusion Eagle Instruction Manual Table of Contents Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 46

Diffusion Eagle Instruction Manual Setup Mode • 45To reset all default alarm point settings:1. From the main menu, select the DEFAULT menu option. The

Página 47 - 42 • Setup Mode Diffusion Ea

46 • Calibration Diffusion Eagle Instruction ManualCalibrationCalibrate the Eagle when you replace a sensor. Also calibrate the Eagle periodically to

Página 48

Diffusion Eagle Instruction Manual Calibration • 47Calibrating the EaglePress and hold the SHIFT/▼ button, then press the DISP/ADJ button. The Calibra

Página 49 - Returning to Default Settings

48 • Calibration Diffusion Eagle Instruction Manual3. To adjust the values on the screen, hold down the SHIFT/▼ button, and press the DISP/ADJ button.

Página 50

Diffusion Eagle Instruction Manual Calibration • 4912. Press the SHIFT/▼ button to place the prompt next to the NORMAL OPERATION menu option, then pre

Página 51 - Calibration

50 • Calibration Diffusion Eagle Instruction Manual5. With the Eagle and Remote Detector properly set up for calibration (see “Preparing for Calibrati

Página 52 - Calibrating the Eagle

Diffusion Eagle Instruction Manual Maintenance • 51MaintenanceDisplaying the Battery VoltageCheck the battery voltage periodically. Replace or recharg

Página 53 - 48 • Calibration Diffusion Ea

52 • Maintenance Diffusion Eagle Instruction ManualEagle battery charger can determine if alkaline batteries are installed and will stop charging them

Página 54

Diffusion Eagle Instruction Manual Maintenance • 53Replacing the combustibles sensorReplace the combustibles sensor when:• The combustibles channel ca

Página 55 - ▼ button

54 • Maintenance Diffusion Eagle Instruction Manual4. Inside the Remote Detector case, unscrew the two screws that secure the retainer plate to the ca

Página 56 - Maintenance

Diffusion Eagle Instruction Manual Introduction • 1 Introduction OverviewThe RKI Standard Diffusion Eagle is the most advanced portable gas detection

Página 57 - Replacing Sensors

Diffusion Eagle Instruction Manual Maintenance • 557. Remove the sensor.8. Install the replacement sensor in reverse order. When plugging in the wire

Página 58

Diffusion Eagle Instruction Manual Maintenance • 566. Remove the sensor.7. Install the replacement sensor in reverse order. When plugging in the wire

Página 59 - Replacing the oxygen sensor

Diffusion Eagle Instruction Manual Appendix A: Parts List • 57Appendix A: Parts ListTable 6 lists part numbers for the Eagle’s replacement parts and a

Página 60

Diffusion Eagle Instruction Manual Appendix B: Methane Elimination • 58Appendix B: Methane EliminationFor applications where methane is an interfering

Página 61

Diffusion Eagle Instruction Manual Appendix B: Methane Elimination • 593. Perform the demand zero procedure as described in “Preparing for Calibration

Página 62 - Appendix A: Parts List

Diffusion Eagle Instruction ManualAppendix C: Installing the Optional Data Logger Board Appendix C: Installing the Optional Data Logger BoardAppendix

Página 63

Diffusion Eagle Instruction ManualAppendix C: Installing the Optional Data Logger Board

Página 64

2 • Introduction Diffusion Eagle Instruction ManualAbout this ManualThis manual is intended for use with the Eagle portable gas detection system. Exam

Página 65

Diffusion Eagle Instruction Manual Specifications • 3SpecificationsTable 1 lists physical and environmental specifications for the Eagle. Table 2 lists

Página 66

4 • Specifications Diffusion Eagle Instruction ManualTable 2 lists specifications for the Eagle’s standard sensors. Your Eagle model may not include al

Comentários a estes Manuais

Sem comentários